Energy consumption

The device is connected to 230V and draws 3.5A current. Power consumption is 1932kJ. How many minutes has this device been in operation?

Correct answer:

t =  40 min

Step-by-step explanation:

U=230 V I=3.5 A W=1932 kJ J=1932 1000  J=1932000 J  P=U I=230 3.5=805 W  W=Pt  t1=W/P=1932000/805=2400 s  t=t1 min=t1/60  min=2400/60  min=40 min



Did you find an error or inaccuracy? Feel free to write us. Thank you!






avatar




Tips to related online calculators
Do you want to convert time units like minutes to seconds?

You need to know the following knowledge to solve this word math problem:

Related math problems and questions:

  • Electric work
    bulb Calculate the work done by the electric forces passing the current of 0.2 A through the bulb in 10 minutes if the bulb is connected to a 230 V power supply.
  • Cooker
    kWMeter A current of 2A passes through the immersion cooker at a voltage of 230V. What work do the electric field forces in 2 minutes?
  • Electric input power
    resistor Solve problems related to electric power: a) U = 120 V, I = 0.5 A, P =? b) P = 200 W, U = 230 V, I =? c) I = 5 A, P = 2200W, U =?
  • Transformer
    transformator Transformer - U1 = 230 V, N1 = 300, N2 = 1,200, I1 = 4 A. Calculate the transformation ratio, voltage and current in the secondary coil.
  • Resistance
    bulb Determine the resistance of the bulb with the current 200 mA and is in a regular lamp (230V).
  • Mains voltage
    bulb How much electric current flows through the appliance with a resistance of 40kΩ, which is connected to the mains voltage (230 V)?
  • Coils of transformer
    transformator The primary coil of the transformer has 400 turns, a current of 1.5 A passes through it and is connected to a voltage of 220 V. For the secondary coil, find the voltage, current, and a number of turns if the transformation ratio k = 0.1.
  • The output
    transformator The output voltage of the transformer is 880 V. The secondary coil has 1200 turns. Find the voltage to which the primary coil is connected and how many turns it has if a current of 1 A flows through it. Transformation ratio k = 4. What current flows throu
  • Current in the conductor
    ohms-law Calculate the current in the conductor (in mA) if it is connected to a 4.5 V voltage source and its resistance is 20 (ohm).
  • Resistance
    Rezistor A resistor having an electrical resistance of 1.5 k ohms passes an electrical current of 0.1 A. Calculate what voltage is between the terminals of the resistor.
  • The bulb
    bulbs What is the resistance of a filament lamp when it is connected to a 9V battery and has a current of 120 mA?
  • Orlík hydroelectric plant
    1280px-Orlík The Orlík hydroelectric power plant, built in 1954-1961, consists of four Kaplan turbines. For each of them, the water with a flow rate of Q = 150 m3/s is supplied with a flow rate of h = 70.5 m at full power. a) What is the total installed power of the p
  • Filament of bulb
    bulb The filament of bulb has a 1 ohm resistivity and is connected to a voltage 220 V. How much electric charge will pass through the fiber when the electric current passes for 10 seconds?
  • The bulb
    bulbs The bulb has a reading of 6V-0.05 A, what current flows through the bulb if we connect it to a cell with a voltage of 12V?
  • Lowest voltage
    inSeries Three resistors with resistors R1 = 10 kΩ, R2 = 20 kΩ, R3 = 30 kΩ are connected in series and an external voltage U = 30 V is connected to them. On which resistor is the lowest voltage?
  • Kirchhoff's law
    resistor Two resistors with 100 Ω and 300 Ω resistors are connected in series. A current of 1.8 A passes through the first 100Ω resistor. What current flows through the second resistor?
  • Transformer
    trafo Solve the textbook problems - transformer: a) N1 = 40, N2 = 80, U2 = 80 V, U1 =? b) N1 = 400, U1 = 200 V, U2 = 50 V, N2 =?